Method for Determination of Hg Concentration in Stack Gas Using Carbon Traps

dc.contributor.authorUnited Nations Environment Programme
dc.contributor.authorScientific Research Institute for Atmospheric Air Pollution
dc.contributor.organizationEcosystems Division
dc.date.accessioned2017-12-07T11:18:06Z
dc.date.available2017-12-07T11:18:06Z
dc.date.issued2017-05
dc.descriptionBecause of the toxicity of Hg, it is important to know the amount of Hg emissions released by point sources. Several methods are available to measure Hg emissions. These methods differ in level of complexity, application conditions, and their ability to speciate Hg. The scope of this document is description of the procedure for the determination of vapor phase Hg mass concentration in stack gas using carbon traps based on US EPA Method 30B. The procedure can be applied in countries around the world.en
dc.formatText
dc.identifier.urihttps://wedocs.unep.org/handle/20.500.11822/22294
dc.languageEnglish
dc.page.number59 p.
dc.subjectmercury
dc.subjectmercury contamination
dc.subject.sdgSDG 13 - Climate Action
dc.titleMethod for Determination of Hg Concentration in Stack Gas Using Carbon Trapsen
dc.typeMeeting resource
wd.identifier.collectionPublications and Documentsen

Download

Original bundle

Showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Report-Mercury SOP 20170519.pdf
Size:
1.09 MB
Format:
Adobe Portable Document Format
Description:
English

Collections