RT null T1 Determination of Total Dissolved Cadmium in Sea-Water by Differential Pulse Anodic Stripping Voltammetry: Reference Methods for Marine Pollution Studies No. 18 A1 United Nations Environment Programme, A1 Intergovernmental Oceanographic Commission, K1 chemical K1 electrochemistry K1 cadmium YR 1983 FD 1983 LK https://wedocs.unep.org/handle/20.500.11822/30755 UL https://wedocs.unep.org/handle/20.500.11822/30755 NO This reference method describes an electrochemical technique for the determination of total dissolved cadmium in sea and estuarine waters. Detection limit is 1 ng of cadmium per kilogram of sea-water using a mercury film rotating electrode (MEE). DS UN Environment Document Repository RD Sep 21, 2026