Passive Sampling of Mercury in Ambient Air Methodology and Procedure

dc.contributor.approvalRecordDirector, Industry and Economy Division
dc.contributor.authorUnited Nations Environment Programme
dc.contributor.organizationIndustry and Economy Division
dc.date.accessioned2026-05-28T05:59:16Z
dc.date.issued2026-04
dc.date.submitted2026-05
dc.descriptionThis standard operating procedure (SOP) provides support to the Global Chemicals Monitoring Programme (GCMP) and its child projects in different UN regions. The GCMP includes six child projects in participating countries from Africa, Asia and Pacific Islands, and Latin America and the Caribbean, with financial support from the Global Environment Facility (GEF). It aims to provide scientifically robust evidence for evaluating the effectiveness of the Stockholm Convention on Persistent Organic Pollutants (POPs) and the Minamata Convention on Mercury thereby facilitating a comprehensive global understanding of the concentrations of POPs and mercury in humans and the environment. The objective of this SOP is to describe the step-by-step installation and management of passive air samplers (PAS), namely MerPAS®, for sampling Mercury in air under the GCMP.
dc.description.conventionAgreementMinamata Convention on Mercury
dc.description.reviewStatusinternal review only
dc.description.statusAdopted
dc.description.urihttps://www.unep.org/topics/chemicals-and-pollution-action/pollution-and-health/heavy-metals/mercury
dc.formatpdf
dc.identifier.urihttps://wedocs.unep.org/handle/20.500.11822/49540
dc.languageEnglish
dc.page.number18 p.
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 IGOen
dc.rights.accessLevelPublic
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/igo/
dc.subject.sdgSDG 3 - Good Health and Well-Being
dc.subject.sdgSDG 14 - Life below Water
dc.subject.sdgSDG 15 - Life on Land
dc.subject.themepollution
dc.subject.thememercury contamination
dc.subject.themeair
dc.subject.themeair quality monitoring
dc.titlePassive Sampling of Mercury in Ambient Air Methodology and Procedure
dc.typeCommunication or other resource

Download

Original bundle

Showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
SOP-Passive-sampling-Mercury_AIR.pdf
Size:
1.02 MB
Format:
Adobe Portable Document Format
Description:
English
Loading...
Thumbnail Image
Name:
SOP-Passive-sampling-Mercury_AIR_FR.pdf
Size:
1.01 MB
Format:
Adobe Portable Document Format
Description:
French
Loading...
Thumbnail Image
Name:
SOP-Passive-sampling-Mercury_AIR_SP.pdf
Size:
1017.67 KB
Format:
Adobe Portable Document Format
Description:
Spanish